Distinguish cooling, renewal, filtration, dehumidification and air distribution.

This resource explains the principle, key decisions, common mistakes and the data required to go further.

All resources
A/01
Design principle
Data • Interfaces • Evidence

Air

Key points to retain.

Temperature is only one dimension of comfort and indoor air quality. Renewal, filtration, cooling, heating, humidity, distribution and extraction must be distinguished.

  • A room air conditioner does not guarantee outdoor-air renewal.
  • Too little airflow harms air quality; too much wastes energy and creates noise.
  • Poorly maintained condensate drains and filters become problems themselves.
A/01Principle diagram — project-specific adaptation required
Air conditioning, ventilation and air quality
Air conditioning, ventilation and air quality

Guided reading

Understand the mechanism, then its consequences.

01

Outdoor air and extract

Outdoor air enters in a controlled way and stale air is removed from suitable zones.

02

Filtration

Filters are selected according to pollutants, use and pressure loss.

03

Thermal and moisture treatment

Coils, direct expansion or other systems control temperature and humidity.

04

Supply and return

Jet geometry and grille position avoid dead zones, short circuits and draughts.

Prepare a study

Useful data before reaching a conclusion.

The visitor can begin with these items. ANTA will then determine which measurements and checks are really required.

  • Maximum occupancy
  • Pollutants and activities
  • Airflow or duct data
  • Temperature and humidity
  • Maintenance history

Frequently asked questions

Clear answers without oversimplifying.

01Why does a room smell despite cooling?

Cooling may recirculate air without removing pollutants or bringing enough outdoor air.

02Should CO₂ be measured?

It can be a useful occupancy-related indicator when interpreted with occupancy and other pollutants.

03Why is there water below the unit?

Blocked drain, slope, insulation, tray, pump or surface condensation may be involved.

Essential glossary

Use the right words for the right decisions.

Outdoor air
Air introduced from outside.
Extract
Removal of indoor air.
Condensate
Water formed when moist air cools below its dew point.
Balancing
Adjustment of flows between branches and spaces.

Further reading

Institutional and technical sources.

ANTA content is an original synthesis. These references support verification and further study.

  1. INRS — Ventilation